自動制御
HVAC CABLE TIES 02TSL
‧Material: UL approved Nylon 6/6
‧Flammability: UL94V-2
‧Operation Temp.: -40℃ to 85℃
‧UL181B-C certified (Mechanical Fasteners for use with Flexible Air Ducts and Air Connectors)
‧Designed for use with flexible ducts in HVAC application
‧RoHS certified / CE certified
‧Flammability: UL94V-2
‧Operation Temp.: -40℃ to 85℃
‧UL181B-C certified (Mechanical Fasteners for use with Flexible Air Ducts and Air Connectors)
‧Designed for use with flexible ducts in HVAC application
‧RoHS certified / CE certified
DOUBLE HEAD CABLE TIE 06DH
‧Material: Nylon 6/6
‧Flammability: UL 94V-2
‧Color: Nature & Black
‧Working temperature: -40℃ to 85℃
‧Feature: Dual locking head design provide spacing for parallel bundles
‧Flammability: UL 94V-2
‧Color: Nature & Black
‧Working temperature: -40℃ to 85℃
‧Feature: Dual locking head design provide spacing for parallel bundles
DIN RAILS 85AR
PLASTIC WIRING DUCTS-1.7M 40WD
‧Material: Rigid, high impact, self-extinguishing PVC (gray)
‧Used primarily in control panels, the resticted slot design allows wires to be added or removed by simply deflecting the fingers on the side of the duct.
‧Solid type wiring ducts also available
‧Used primarily in control panels, the resticted slot design allows wires to be added or removed by simply deflecting the fingers on the side of the duct.
‧Solid type wiring ducts also available
CLOSE SLOTTED WIRING DUCTS 40CWD
‧Material: Rigid, high impact, self-extinguishing PVC (gray)
‧Used primarily in control panels, the resticted slot design allows wires to be added or removed by simply deflecting the fingers on the side of the duct.
‧Close slot design provides easy application.
‧Used primarily in control panels, the resticted slot design allows wires to be added or removed by simply deflecting the fingers on the side of the duct.
‧Close slot design provides easy application.
PLASTIC WIRING DUCTS-2M 42WD
‧Material: Rigid, high impact, self-extinguishing PVC (gray)
‧Used primarily in control panels, the resticted slot design allows wires to be added or removed by simply deflecting the fingers on the side of the duct.
‧Solid type wiring ducts also available
‧Used primarily in control panels, the resticted slot design allows wires to be added or removed by simply deflecting the fingers on the side of the duct.
‧Solid type wiring ducts also available
TIE MOUNTS(SELF-ADHESIVE) 08SDM
‧Material: Nylon 6/6,With quality adhesive
‧Flammability: UL 94V-2
‧Color: Natural or Black
‧2 pieces a pair is also available
‧Y.Y. Cable ties can be inserted from any of the 4 ways-saving orientation tie
‧Test to comply with UL 62275
‧Flammability: UL 94V-2
‧Color: Natural or Black
‧2 pieces a pair is also available
‧Y.Y. Cable ties can be inserted from any of the 4 ways-saving orientation tie
‧Test to comply with UL 62275
NYLON CABLE GLANDS-70 MM 70MM
‧Material: UL approved polyamide; EPDM for seal insert (other NBR material is also available)
‧Flammability: UL 94V-2
‧Color: Black, Grey, Light Grey
‧Flammability: UL 94V-2
‧Color: Black, Grey, Light Grey
NYLON CABLE GLANDS-72 NPT 72NPT
‧Material:UL approved Nylon 6/6; Neoprene for seal insert
‧Flammability: UL 94V-2
‧Color: black, gray, or Light gray
‧Protection: IP68
‧Temp. resistance: -30°C to 80°C; short time140°C
‧Flammability: UL 94V-2
‧Color: black, gray, or Light gray
‧Protection: IP68
‧Temp. resistance: -30°C to 80°C; short time140°C
NYLON CABLE GLAND 70PG
‧Material: UL approved polyamide; EPDM for seal insert (other NBR material is also available)
‧Flammability: UL 94V-2
‧Color: Black, Grey, Light Grey
‧Protection: made to comply with IP68
‧Operating temperature: -40°C up to +100°C
‧PG series is equipped with cable gland body, seal and lock nut only
‧Applied to machines, control cabinets, instruments for cable installation
‧Features: Easy and quick assembling with good strain relief
‧Flammability: UL 94V-2
‧Color: Black, Grey, Light Grey
‧Protection: made to comply with IP68
‧Operating temperature: -40°C up to +100°C
‧PG series is equipped with cable gland body, seal and lock nut only
‧Applied to machines, control cabinets, instruments for cable installation
‧Features: Easy and quick assembling with good strain relief
STRAIN-RELIEF BUSINGS 21SRB
‧Material: Nylon 6/6
‧Color: Black
‧Flammability: UL94V-2
‧To insulate and protect AC cords
‧Color: Black
‧Flammability: UL94V-2
‧To insulate and protect AC cords
SPIRAL WRAPPING BAND 20SB
‧Material: PE
‧Color: Natural & Black
‧Fix end of band with YY ties and spiral band in clockwise direction
‧Remark: Flexible, Durable, Reusable
‧All sizes are available for "roll" packing upon request (SBP series)
‧Color: Natural & Black
‧Fix end of band with YY ties and spiral band in clockwise direction
‧Remark: Flexible, Durable, Reusable
‧All sizes are available for "roll" packing upon request (SBP series)
WIRE-NUT CONNECTORS 30E
‧Material: Tough thermoplastic shell (Flame-retardant UL94V-2) with steel spring inserted
‧E1 & E3 rated at 150℃ (black color) are also available upon requested
‧Follow UL 486C and CSA 22.2 No. 188 standard
‧Rated at 600V Max. for building wiring and 1000V Max. in lighting fixtures/ luminaries and signs
‧E1 & E3 rated at 150℃ (black color) are also available upon requested
‧Follow UL 486C and CSA 22.2 No. 188 standard
‧Rated at 600V Max. for building wiring and 1000V Max. in lighting fixtures/ luminaries and signs
ULTRA CONNECTORS 30UC
‧Material: Housing is Polycarbonate (PC) or Nylon 6/6, flame-retardant to UL 94V-2
Sleeve is Copper, tin plated, spring steel for UC-2~UC-5 and steel plate with copper strip for UC-8
‧Housing is Nylon 6/6 Working temperature: T110°C (IEC), 105°C/221°F (UL)
‧Rated at 600V Max. for building wiring and 1000V Max. in lighting fixtures/ luminaries and signs
‧UC-8 is only available for PC material.Working temperature: T85°C
Sleeve is Copper, tin plated, spring steel for UC-2~UC-5 and steel plate with copper strip for UC-8
‧Housing is Nylon 6/6 Working temperature: T110°C (IEC), 105°C/221°F (UL)
‧Rated at 600V Max. for building wiring and 1000V Max. in lighting fixtures/ luminaries and signs
‧UC-8 is only available for PC material.Working temperature: T85°C
INSULATED FORK/ SPADE TERMINALS 37SVY
‧Terminal Material:Copper
‧Maximum Electrical Rating:105℃,600 VOLYS MAX
‧Insulated Material:Vinyl(PVC)
‧Maximum Electrical Rating:105℃,600 VOLYS MAX
‧Insulated Material:Vinyl(PVC)
RING NON-INSULATED TERMINAL 38RNB
‧Material:Copper
SPADE NON-INSULATED TERMINAL 38SNB
‧Material:Copper
NYLON CABLE TIES 01TSL
‧Material: UL approved Nylon 6/6
‧Flammability: UL 94V-2
‧Working Temp.: -40°C to 85°C
‧Color: stock in Natural (other colors are also available)
‧Made to comply with MIL-SPEC M20693B, tensile strength meet
‧Remark: Complete range, stable quality and low insertion
‧Flammability: UL 94V-2
‧Working Temp.: -40°C to 85°C
‧Color: stock in Natural (other colors are also available)
‧Made to comply with MIL-SPEC M20693B, tensile strength meet
‧Remark: Complete range, stable quality and low insertion
MARKER TIES 05MT
‧Material: Nylon 6/6
‧Flammability: UL 94V-2
‧Color: Natural
‧For use: Identifying telephone and fiber optic cable
‧Flammability: UL 94V-2
‧Color: Natural
‧For use: Identifying telephone and fiber optic cable
PUSH MOUNT TIES-PT 06PT
PUSH MOUNT TIES-PMT 06PMT
POLYAMID 12 LASHING TIES 06LT
‧Material: Nylon 12
‧Color: Black
‧For use: Used widly in external applications; especially good in a "salt atmosphere" environment
※Temporary not available
‧Color: Black
‧For use: Used widly in external applications; especially good in a "salt atmosphere" environment
※Temporary not available
CABLE TIES AND FIR TREE MOUNT ASSEMBLIES 06FTHH1-6
Cable ties
‧ Material: Nylon6/6 impact modified, heat stabilized, UV resistant
‧ Flammability: UL 94V-2 / UL 94HB
‧ Color: Black
‧ Working temperature: -40℃ to +105℃
‧ Other material and size are also available upon request
‧ Material: Nylon6/6 impact modified, heat stabilized, UV resistant
‧ Flammability: UL 94V-2 / UL 94HB
‧ Color: Black
‧ Working temperature: -40℃ to +105℃
‧ Other material and size are also available upon request
Mounts (FTM1, FTM2, FTM3,FTM4,FTM5 and FMT6)
‧ Material: Nylon 6/6 impact modified, heat stabilized, UV resistant
‧ Flammability: UL 94V-2 / UL 94HB
‧ Color: Black
‧ Working temperature: -40℃ to +110℃
‧ Other material and size are also available upon request
‧ RoHS. CE certified
TIE MOUNTS(SADDLE TYPE) 08STM
‧Material: Nylon 6/6‧Flammability: UL 94V-0
‧Color: Natural or Black
‧Unique cradle design provides maximum stability and rigdity to the wire bundle
‧Color: Natural or Black
‧Unique cradle design provides maximum stability and rigdity to the wire bundle
CABLE CLAMPS 08CC
‧Material: Nylon 6/6
‧Flammability: UL 94V-2
‧Color: Natural or Black
‧Flammability: UL 94V-2
‧Color: Natural or Black
SELF-ADHESIVECABLE CLAMP 09ACC/AWC
‧Material: Nylon 6/6
‧Flammability: UL 94V-2
‧Color: Black (natural also available upon request)
‧Flammability: UL 94V-2
‧Color: Black (natural also available upon request)
FLEXIBLE CONDUIT FITTINGS 76FCF
‧Material: UL approved polyamide 66
‧Flammability : UL94 V-2
‧Color: Black, Grey
‧Operating Temp. : -40°C up to 100°C
‧Flammability : UL94 V-2
‧Color: Black, Grey
‧Operating Temp. : -40°C up to 100°C
MOVABLE BUSHING 21MB
‧Material: PE
‧Color: Natural
‧Cut to fit any hole sizes for protecting cords, wires and cables against damage from sharp panel edges.
‧Remark: Flexible, Durable, Reusable
‧Color: Natural
‧Cut to fit any hole sizes for protecting cords, wires and cables against damage from sharp panel edges.
‧Remark: Flexible, Durable, Reusable
CLOSED-END CONNECTORS 30CE
‧Material: Housing is Nylon 6/6, flame-retardant to UL94V-2
Sleeve is Aluminum, tin plated and copper,tin plated
‧Just peel off wires,insert them into connector tube and press with crimping tool
‧Rating: 300 V Max. Temp 105°C (221°F)
Sleeve is Aluminum, tin plated and copper,tin plated
‧Just peel off wires,insert them into connector tube and press with crimping tool
‧Rating: 300 V Max. Temp 105°C (221°F)
VINYL END CAP 22ECV
‧Material: Soft PVC
‧Color: Red, White, Yellow, Blue, Green, Black, Brown
‧Temp: Rating 80℃, Voltage 300V
‧Remark: For the insulation works of wire end terminal
‧Color: Red, White, Yellow, Blue, Green, Black, Brown
‧Temp: Rating 80℃, Voltage 300V
‧Remark: For the insulation works of wire end terminal
HOLE PLUGS 21HP
‧Material: Nylon 6/6
‧Color: Black (white color is available upon request)
‧Flammability: UL94V-2
‧Be installed with fingertip pressure into unneeded hole, stay smooth appearance
‧Color: Black (white color is available upon request)
‧Flammability: UL94V-2
‧Be installed with fingertip pressure into unneeded hole, stay smooth appearance
SNAP BUSHINGS 21SB/21OCB/21RSB
‧Material: Nylon 6/6
‧Color: Black
‧Flammability: UL94V-2
‧Smooth and insulate the raw edged holes in metal chassis
‧Color: Black
‧Flammability: UL94V-2
‧Smooth and insulate the raw edged holes in metal chassis
PVC TUBE 26PT
‧Material: PVC
‧Color: Black
‧Working Temp.: -40°C ~ 105°C
‧Color: Black
‧Working Temp.: -40°C ~ 105°C
INSULATED RING TERMINALS 37RVR
‧Terminal Material:Copper
‧Maximum Electrical Rating:105℃,600 VOLTS MAX
‧Insulated Material:Vinyl(PVC)
‧Maximum Electrical Rating:105℃,600 VOLTS MAX
‧Insulated Material:Vinyl(PVC)